26. Waning Lamps
Checks when the SYNC CLOCK switch is set to DI
Input the signal
correctly.
Set the sampling
frequency correctly.
Checks when the SYNC CLOCK switch is set to REMOTE 3
Input the signals
correctly.
Set the sampling
frequency correctly.
76
Warning Lamps
Is a signal input to the AES/
EBU D-I connector?
No
Does the sampling frequency of
the signal input to the AES/EBU
D-I connector agree with the
No
setting on the PCM recorder?
AES/EBU board faulty.
Are word sync signal and
sector sync signal input to
the REMOTE-3 connector
No
from the remote control unit?
Does the sampling frequency of
the word sync signal input to the
REMOTE-3 connector agree with the
No
setting on the PCM recorder?
SRIF-3 board faulty.
Yes
Yes
Yes
Yes