CTK board
FS (sampling frequency) SHIFT lamp
This lights when the FS SHIFT switch is on.
CTL JUMP lamp
This lights whenever there is a discontinuity in the CTL addresses.
CRC ERR or ERROR (cyclic redundancy check error) lamp
This lights when there is a CRC error in the CTL played back.
CTL COPY switch
Determines whether or not to copy CTL data together with the digital audio signals
when making a backup copy.
ON: copy the CTL data.
OFF: do not copy the CTL data. (factory setting)
REF (reference) VIDEO switch
Selects the signal to be input to the REFERENCE VIDEO INPUT connector on the
rear panel.
NORM: NTSC or PAL composite video signal
: square wave (30 Hz, 29.97 Hz, 25 Hz, 24 Hz)
EXT (external) SYNC switch (PCM-3348HR only)
Set the range in which the PCM-3348HR is synchronized with an external sync
signal (clock accuracy).
WIDE: To permit the PCM-3348HR to synchronize with an external word sync
signal of 38.54 to 54.0 kHz.
The tape transport speed can be adjusted when the PCM-3348HR is being
synchronized with the reference video signal (including the phase adjustment
operation).
NARROW: To permit the PCM-3348HR to synchronize with an external word sync
signal which is ± 50 ppm of the selected sampling frequency.
The tape transport speed cannot be adjusted when the PCM-3348HR is being
synchronized with the reference video signal.
FS (Sampling frequency) SHIFT switch
Shifts the sampling frequency.
Switches and Lamps on Internal Boards
(Continued)
65