3 Controller

3.3.2 Installation dimensions

The following figures show the dimensions required installing the controller.
For the placement of the controller on its side (the horizontal installation), two stacks is permitted.
Horizontal installation
Vertical installation
150mm
Fig.3-3: Installation dimensions
CAUTION
CAUTION
3-36 Outside dimensions/Installation dimensions
145mm
170mm
Fixing installation section sure for prevention from the fall, when using the controller
placing vertically. The reference figure of the metal plate for fixing is shown in
4.
You should install the metal plate for fixation to the controller with M4 x 8 or the
shorter screw. The screw projection length inside the controller (side board thickness
is 1.2 mm) surely makes 6.8 mm or less.
When storing the controller in a cabinet, etc., take special care to the heat radiating
properties and ventilation properties so that the ambient temperature remains within
the specification values. And, don't install the controller in the position where direct
rays or the heat of lighting hits. The skin temperature of the controller may rise, and
the error may occur.
Air intake
Air intake
145mm
150mm
50mm
20mm
Fig. 3-