01
Fault table for models 10.97 ä (2
Display on V.A.G 1552
00000
no fault detected
66535
control unit defective
00849
S contact on ignition starter
switch D
undefined switch status
00912
switch for window lifter FL -E40
implausible signal
short-circuit to earth
00913
switch for window lifter FR, driver
-E81
implausible signal
short-circuit to earth
00914
switch for window lifter RL, driver
-E53
implausible signal
short-circuit to earth
00915
switch for window lifter RR, -E55
implausible signal
short-circuit to earth
------------ 01-29.1 ------------
Self-diagnosis
nd
generation convenience system)
Possible fault cause
If after the repair is completed 'no fault detected' is displayed the self-diagnosis is ended.
♦ control unit defective
♦ defective wires or plug connec-
tions
♦ terminal 15 OK, S contact defec-
tive
♦ defective wires or plug connec-
tions
♦ defective wires or plug connec-
tions
♦ defective window lifter switch
passeng. side -E40
♦ tip switch fitting NOK, jams when
operated
♦ defective wires or plug connec-
tions
♦ defective window lifter switch RL
-E81
♦ tip switch fitting NOK, jams when
operated
♦ defective wires or plug connec-
tions
♦ defective window lifter switch RL
side -E53
♦ tip switch fitting NOK, jams when
operated
♦ defective wires or plug connec-
tions
♦ defective window lifter switch RR
-E55
♦ tip switch fitting NOK, jams when
operated
Fault elimination
- replace control unit
- check wires and plug connections with current
flow diagram
- read measured value block, display group
number 10 ⇒ page 01-40.5
- check wires and plug connections with current
flow diagram
- check wires and plug connections with current
flow diagram
- replace switch
- check switch
- read measured value block, display group
number 002 ⇒ page 01-40.1
- check wires and plug connections with current
flow diagram
- replace switch
- check switch
- read measured value block, display group
number 002 ⇒ page 01-40.1
- check wires and plug connections with current
flow diagram
- replace switch
- check switch
- read measured value block, display group
number 002 ⇒ page 01-40.1
- check wires and plug connections with current
flow diagram
- replace switch
- check switch
- read measured value block, display group
number 002 ⇒ page 01-40.1
OCTAVIA
Edition 12.98
S00.5118.55.20

Hide quick links: