Create MyConfig - Expert
4.6 Script language
DoVar(<axis>)
Generates a DO variable using the permanently defined machine axis identifier <axis>.
Example:
Up.myVar2 = DoVar(AX1)
4.6.12.7
Log
Log ("<label>")
Logbook entry
Any message text that is only written in the logbook represents the <label> argument.
Example
Giving the logbook entries a yellow background makes the logbook easier to read.
Log("<span style='background-color:#FFFF99'>My notes in the CMC
logbook.</span>")
4.6.12.8
Logging
Logging (<switch>)
Logging in the logbook can be deactivated and reactivated.
For the <switch> argument, the "On" values are used for activating and the "Off" values for
deactivating.
Note
The logging is automatically reset to "On" at the end of the script (dialog/step script/task).
330
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE