Siemens SINUMERIK 840D sl Operating Manual page 143

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

You can find an overview for the dependencies of the dialog pages of data areas (Page 144)
in the section with the same name.
Show/hide inactive dialogs button
With the
be shown or hidden.
Defining general properties for all dialogs
Generally applicable properties can be defined for all dialogs.
Name
In the table column below "Name", dialog pages with a black checkbox can be activated or
deactivated for "Editing" directly in the dialog list or via the property "Edit" in the property field.
Dialog pages with a gray checkbox are always required to execute the package, in accordance
with the configuration of the areas in the "Package" tab, and cannot be deselected.
Editing mode for all dialogs
By right-clicking one of the table columns (Name, Mode or Messages) or a dialog page, you
can uniformly define the Mode property for all dialogs: "Editing mode for all dialogs".
The following options are offered and are activated when the package is executed:
Manual
Automatic
Progress
Display messages for all dialogs
Also by right-clicking one of the table columns (Name, Mode or Messages) or on a dialog page,
you can uniformly define the Messages property for all dialogs: "Display messages for all
dialogs".
The following options are available:
Error
Errors and warnings
All
Using the dialog list, you can centrally view the editing mode and message display for all
dialogs, and select individually or for all dialogs (context menu).
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
button (Show/hide inactive dialogs), dialogs that are not enabled in this project can
The dialog page is completely displayed, the operator can make changes
and must trigger the dialog page advance or execution.
The dialog page is completely displayed, however, the operator cannot make
any changes and it is executed automatically.
Processing is analogous to the Automatic mode without the configuration
information being displayed.
The "Display messages" property specifies which messages for the 840D or
CMC system are displayed during the package execution. Messages to be
suppressed are acknowledged via the automatic actuation of the standard
button.
Messages and dialogs from the (Error, Warning, Msg, Input ...) script are
always displayed.
If these user messages should also be hidden, the users must do this them‐
selves using corresponding system variables and conditions.
Create MyConfig - Expert
4.4 Project folder
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents