System Variables For The Dialogs Tab; System Variables For The Package Configuration Dialog - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Expert
4.8 Reference list, system variables
Enumeration language preselection - Language
Area
Enumeration
Enumeration language preselection - Language
Up.$Pack.Languages.
DEU
ENG
FRA
ITA
CHS
ESP
4.8.3

System variables for the Dialogs tab

The following system variables are assigned to the Dialogs tab (Page 142) and are addressed
using the prefix Up.$Dialog.
For all system variables, the time until a change of the system variables makes sense and is
still effective for the package execution is specified in the "Change effective until" table column.
4.8.3.1

System variables for the Package configuration dialog

Table 4-40
"Package configuration" dialog - PackageConfig (Dialog ID)
System variables
Type
Up.$Dialog.PackageConfig.
Activated
BOOL
ProcessMode
Enumeration Process‐
Mode (Page 382)
InteractLevel
Enumeration InteractLe‐
vel (Page 383)
CfgFile
STRING
See also
Package configuration (configuration) (Page 151)
372
Type
Change effective until
Enumerator value
readOnly
Change effective until Description
readOnly
Activating the dialog processing,
such as:
Current dialog → OnI‐
Enumeration processing mode
nit
Enumeration message level
Configuration preselection
Description
Language preselection German
Language preselection English
Language preselection French
Language preselection Italian
Language preselection Chinese (sim‐
plified)
Language preselection Spanish
Configured in Expert
Specified by an "*.upcfg" file
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Example
false / true
Up.
$Dialog.ProcessModes.MA
NUAL
Up.
$Dialog.InteractLevels.
ALL
"myMachine_01.upcfg"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents