Siemens SINUMERIK 840D sl Operating Manual page 221

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Information on the system variables·can be found in the System variables for the NCU/PPU
result state dialog (Page 381) section.
Further general information on the system variables can be found in the Reference list system
variables (Page 368) section.
Dialog
More detailed information about the "Dialog" property group can be found at Package
configuration (configuring) (Page 153).
Data backup CF card
The "NCU/PPU result state" dialog page can be used to backup all data of the NCU/PPU that
runs under the Linux operating system.
The following settings are available for the "Data backup CF card" and are activated when the
package is executed:
Perform backup
Setting disabled
Archive
The settings for the "archive" are defined by the project engineer and are not displayed during
package execution.
The "archive" can be used for diagnostics. It is not required for the production or the upgrade
of a machine.
The following settings are available for the "archive":
Back up archive
Dialog scripts
In the "Dialog scripts" property, "Scripts" entry, click the
dialog.
You can edit scripts here that are to be executed at selectable times during package execution.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Yes
Here, you specify whether a data backup of the CF card including the archive data
for the NC, PLC and DRV areas is to be created after the package execution.
No
With the setting "Yes", the data backup is saved with the name '<CF-Karten-
ID>_result.tgz'.
The file is stored in the folder based on the name of the CF card ID which is located
next to the package after the package execution.
Yes
Here, you specify whether the settings made during the configuration are to be
blocked so that they can only be viewed by the operator, but not changed.
No
Yes
Here, you specify whether an archive with the NC, PLC and DRV areas is created
after the execution of the package.
No
The backup is performed for the NC area with the setting that all data is to be saved.
For setting "Yes", the archive is saved with the name 'Result_<Datum>.arc'.
The archive is stored in the folder based on the name of the CF card ID which is
located next to the package after the package execution.
Create MyConfig - Expert
4.4 Project folder
button to call the "Dialog scripts"
221

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents