Xsd For Xml-Interface - Siemens SINUMERIK 840D sl Operating Manual

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Topo
6.9 Interface Topo XML
<motor_module nam="eMM1" dovar="var1" dotype="11" donr="20"
doname="do">
</motor_module>
Non-DRIVE-CLiQ components (motor, encoder, sine_filter_module) must be adequately
defined using their subordinate hierarchical position.
The "cliq" element designates a port of a DRIVE-CLiQ component. The "index" attribute
specifies the last position of the terminal designation (for X104 → 4, for X501 → 1, etc.).
The "uplink=true" attribute in the "CLiQ" element specifies that it involves an "incoming
connection" from a higher-level component.
Each component can be assigned an ID using the "oemid" attribute.
This ID is written to SINAMICS parameter p7859[component number] in DO1. Using this
parameter, the machine manufacturer can address additional information, such as additional
error texts, spare part numbers, etc.
In order to use a comparison topology to generate a user-specified topology without further
manual processing in Topo, a unique name as well as a unique component number for each
slave ("compnr/compnr2" attribute) must be assigned for each component.
To deactivate individual components of a DO or whole DOs, the "compstate" and "dostate"
attributes with appropriate valid values can be assigned to the corresponding components.
6.9.3

XSD for XML-interface

<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:xs="http://www.w3.org/2001/XMLSchema"
elementFormDefault="qualified" attributeFormDefault="unqualified">
<xs:annotation>
</xs:annotation>
<xs:simpleType name="uInt">
516
<cliq index="0" uplink="true"/>
<cliq index="1"/>
<cliq index="2">
<sensor_module name="SM1" group="DQI_01" doref="var1" sm="1">
<cliq index="0" uplink="true"/>
</sensor_module>
</cliq>
<xs:documentation>
Content: ECAD XML interface
Version: 4.8
Date: 30.08.16
</xs:documentation>
<xs:union>
<xs:simpleType>
<xs:restriction base="xs:unsignedInt"/>
</xs:simpleType>
<encoder name="Enc1" group="DQI_01"/>
<motor name="Mot1" group="DQI_01"/>
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d