Siemens SINUMERIK 840D sl Operating Manual page 44

Integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Create MyConfig - Diff
3.3 SINUMERIK archive comparison
Activate filter
By selecting "Include/exclude data with block numbers or identifiers by way of a filter", the
functionality of the inclusion and exclusion filter is activated.
Note
If a filter is active, then all of the identifiers that have been filtered-out are not displayed and
are also not compared.
The Filter
Define filter, as character string or regular expression
Interpret filter as:
You can define whether the filters should be interpreted as character string or regular
expression. Information on this can be found in Section Use of regular expressions in Diff.
Generally, the filters do not describe complete identifiers, but distinct character strings of the
identifiers which are sufficient to clearly identify the required quantity of identifiers.
Context menu
Filter entries can be created, edited and deleted via the context menu.
Activate or deactivate an exclusion filter
Every filter entry can be individually activated or deactivated.
Example of a filter:
_SAFE_
44
icon is displayed in the status bar.
This filter describes all identifiers that contain the specified character
string.
Generally, these are all the safety data such as $MA_SAFE_IS_ROT_AX,
$MA_SAFE_SINGLE_ENC, etc.