Create MyConfig - Expert
4.4 Project folder
Comparison topology (*.ust)
Note
Prerequisite for comparison topology
On the "SINAMICS topology" dialog page, a comparison topology is always used if, on the
"System configuration" dialog page at DRV archive data / Drive configuration, for "Origin of
data"Initial state, Automatic configuration, or Offline archive has been selected.
On the "SINAMICS topology" dialog page, a comparison topology is always used if, on the
"System configuration" dialog page at DRV archive data / Drive configuration, for "Origin of
data"Initial state, Automatic configuration or Offline archive has been selected.
With the comparison topology, the DRIVE-CLiQ wiring and components are checked based
on the SINAMICS target topology from the DRV archive.
The following properties available for the "comparison topology (*.ust)" are activated when the
package is executed:
List
Preselection
User-specified topology (*.utz)
Note
Prerequisite for user-specified topology
If, on the "System configuration" dialog page, User-specified topology has been selected at
"DRV archive data / Drive configuration > Data source", a configured user-specified topology
always applies.
If no critical inconsistency with the real topology is found by the drive in the user-specified
topology, the user-specified topology is applied as the user-specified target topology of
SINAMICS.
200
Clicking the
button opens the "List of topologies (*.ust)" dialog.
Select the desired topology from the list.
Comparison topologies can be pasted or inserted as link at "List".
These are also saved in the package during deployment and can be selected
during package execution.
Select a topology that is to be preselected for the package execution.
Alternatively, enter the path of a file which is located next to the package "/
<Path>/<File>", e.g. "Comparison topology.ust".