Detailed Description
2.4 Selectable spindles
Basic position SD42800
After switching on the NC in installation switch position 1 (Delete SRAM)
the setting data:
SD42800 $SC_SPIND_ASSIGN_TAB[...]
is in the basic position.
The numbers of the logical and physical spindles are identical.
SD42800 $SC_SPIND_ASSIGN_TAB[1] = 1
SD42800 $SC_SPIND_ASSIGN_TAB[2] = 2
SD42800 $SC_SPIND_ASSIGN_TAB[3] = 3
SD42800 $SC_SPIND_ASSIGN_TAB[4] = 4
SD42800 $SC_SPIND_ASSIGN_TAB[5] = 5
...
Example
Assumptions: Spindle configurations:
Specifying the spindle number and machine axis
MD35000 $MA_SPIND_ASSIGN_TO_MACHAX [AX4] = 1
MD35000 $MA_SPIND_ASSIGN_TO_MACHAX [AX5] = 2
MD35000 $MA_SPIND_ASSIGN_TO_MACHAX [AX6] = 3
MD35000 $MA_SPIND_ASSIGN_TO_MACHAX [AX7] = 5
Applying a machine axis in the channel
MD20070 $MC_AXCONF_MACHAX_USED[0] = 4
MD20070 $MC_AXCONF_MACHAX_USED[1] = 5
MD20070 $MC_AXCONF_MACHAX_USED[2] = 6
MD20070 $MC_AXCONF_MACHAX_USED[3] = 7
Specifying the master spindle
MD20090 $MC_SPIND_DEF_MASTER_SPIND = 1
Spindle number converter
MD20092 $MC_SPIND_ASSIGN_TAB_ENABLE = 1
SD42800 $SC_SPIND_ASSIGN_TAB[0] = 1
SD42800 $SC_SPIND_ASSIGN_TAB[1] = 1
SD42800 $SC_SPIND_ASSIGN_TAB[2] = 2
SD42800 $SC_SPIND_ASSIGN_TAB[3] = 3
SD42800 $SC_SPIND_ASSIGN_TAB[4] = 0
M3 S1000
...
...
66
Address extension = 1, M1=3 S1=1000 is output. The spindle with the configured No.
"1" (No. of physical master spindle) rotates.
Activate spindle number converter
Master spindle as configured
Basic table setting
Logical spindle not assigned
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0