Table 5-8 Procedure To Load A Program From Memory Using Online Menu (Vpr100/Vrx150 Only); Table 5-9 Procedure To Load A Program From Memory Using Any Profiler Display (Vpr100/Vrx150) - Honeywell VPR100 User Manual

Table of Contents

Advertisement

Setpoint Profiler

Table 5-8 Procedure To Load A Program From Memory Using Online Menu (VPR100/VRX150 only)

Step
1
If instrument is not in online mode, press the
Display button to change to online mode.
2
Press the Menu button to display the online
menu.
3
Press Down Arrow button to highlight Setpoint
Profiles.
4
Press Enter.
5
Press Down Arrow button to highlight Load
Program From Memory.
6
Press Enter.
7
Press Enter to select Program Number prompt.
8
Press Up Arrow or Down Arrow to select the
desired program number to be loaded.
9
Press Enter to select
10
Press Enter again to load.

Table 5-9 Procedure To Load A Program From Memory Using Any Profiler Display (VPR100/VRX150)

Step
1
If instrument is not in online mode, press the
Display button to change to online mode.
2
Access the Setpoint Profile Trend display:
Press the Display button until the Setpoint
Profile Trend display is shown.
Or
Press the Display button until a Setpoint Bar
Graph display is shown. Press the Tab button
to move the cursor to the TREND text under
the desired profile at the bottom of the display.
Press Enter to display the Setpoint Profile
Trend display for that profile.
3
Press the Tab button to display the profiler
menu.
4
Press Down Arrow button to highlight LOAD.
5
Press Enter.
6
Press Enter to select Program Number prompt.
7
Press Up Arrow or Down Arrow to select the
desired program number to be loaded.
8
Press Enter.
9
Press Down Arrow to highlight LOAD
PROGRAM FROM MEMORY.
10
Press Enter to select it.
210
Action
Action
VPR & VRX – User Manual
Result/Notes
An online display is shown.
Online menu is displayed.
Cursor moves down.
Setpoint Profiles menu is displayed.
Prompt is highlighted.
Load Program sub-menu is displayed.
Cursor moves to the right.
Program number is displayed.
Program number is selected.
Program is loaded from memory to the
instrument.
Result/Notes
An online display is shown.
Setpoint Profile Trend display is shown.
Profiler menu is shown.
Cursor moves down to LOAD menu item.
LOAD menu is displayed.
Cursor moves to the right.
Program number is displayed.
Program number is selected.
Cursor is on LOAD PROGRAM FROM MEMORY.
Specified Program is loaded from the internal
memory to the specified Profiler.
12/00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrx100Vrx150

Table of Contents