Engine Sensor Checkout - Avidyne Entegra EX5000 MFD Series Installation Manual

Table of Contents

Advertisement

6. Once all points have been calibrated, press Calibration Complete. The calibration factors are
computed and applied to DAU reported fuel quantity.
7. When you are done, press Save. Press Cancel to exit without saving changes.
8. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.
Other options from the Underway state are to Restore Last Cal and Clear Cal:
Press Restore Last Cal to restore the calibration values from the last completed calibration. The
calibration state is change to Calibrated.
Press Clear Cal to clear all calibration values. The state changes to Not Calibrated.
An Are You Sure? prompt gives you the chance to reconsider the decision to either restore or clear the
fuel calculations.
Pressing Cancel from the Underway state causes the current calibration session to end without
saving any interim calibration values.
For the fuel calibration procedure for the 530-00170-000, 530-00180-000, 530-00195-000,
Note:
530-00195-001, 530-00195-010, and 530-00201-000 software, see the Piper Process
Specification document PPS60185.
Torque Calibration (Optional)
For some aircraft, the MFD provides an interface to the Torque Calibration feature. If this feature is
available, the Torque Cal button displays.
For information about using the Torque Calibration feature, see the factory procedures for the aircraft.

5.10.2 Engine Sensor Checkout

After restarting the MFD, view the Engine page to verify data communication. Operate the aircraft
engine to confirm correct operation of all sensors.
The Percent Power function will not operate correctly on some models until the Aircraft Setup has
been completed.
- 72 -
EX5000 Installation Manual
P/N 600-00073 Rev 24