Lightning Sensor Checkout; Table 19: Lightning Sensor Messages - Avidyne Entegra EX5000 MFD Series Installation Manual

Table of Contents

Advertisement

The antenna position setting and stabilization source must agree with the WX-500 jumper
Note:
setting and the physical mounting location of the antenna.
4. For the TWX-670 the following options are available in the TWX-670 Config page:
Enable geo stabilization – an external position source (GPS or FMS) connected to the sensor
will stabilize the lightning strikes to the aircraft position
Enable heading stabilization – an external heading source (e.g., a synchro) connected to the
sensor will stabilize the lightning strikes to the aircraft heading.
Enable Audio Output – if connected to the aircraft audio panel, the TWX-670 will provide
audible warnings concerning nearby lightning strikes.
These options are only available after the Sensor and Port options have been selected and
the MFD restarted. Green check marks will appear next to each option if the TWX-670 agrees
with the configuration. If red X's appear, it may be because another display connected to the
sensor is trying to set a different configuration. Consult the TWX-670 installation manual for
more information.
5. When you are done, press Save. Press Cancel to exit without saving changes.
6. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.
In addition to the settings on the Lightning Setup Page, the following buttons may be available:
WX-500/TWX-670 Diags – allows access to the lightning sensor diagnostic modes. See your
sensor's Installation Manual about how to verify software versions, wiring configurations, antenna
environment, and fault logs (not available on all software releases).
Self Test (WX-500) – Runs the WX-500 Self Test and reports Pass or Fail. See the WX-500
Installation Manual for information about testing and the interpretation of the results (not available
on all software releases).

5.6.2 Lightning Sensor Checkout

After the MFD has been restarted, any of the following messages may appear in the main viewing
screen or the message bar and Setup page.

Table 19: Lightning Sensor Messages

Message
Lightning Sensor is Operating Normally
Lightning Sensor in Demo Mode
Lightning Sensor is in Noise-Monitor Mode
Lightning Sensor in Test Mode
Lightning Sensor ERROR
Lightning Sensor has FAILED
Verifies that strike data to the MFD is valid.
Demo mode has been selected as the operating mode from the
Lightning Setup Page.
Noise-Monitor mode has been selected as the operating mode from
the Lightning Setup Page.
Test mode has been selected as the operating mode from the
Lightning Setup Page.
The sensor system has reported an error that may mean current
data is incomplete or erroneous. The error may clear.
The sensor system has reported an error that may mean current
data is incomplete or erroneous. The error will not clear until power
is removed from and reapplied to the sensor system.
- 44 -
EX5000 Installation Manual
P/N 600-00073 Rev 24
Meaning

Advertisement

Table of Contents
loading

Table of Contents