5.9.2 Roll Trim Adjustment

To adjust the Roll Trim Adjustment:
1. From the Maintenance Mode Page, select Setup Radar.
2. From the Radar Setup page. select Roll Trim.
3. The Roll Trim value appears on the Radar screen and can be modified by the Roll Trim control
knob.
4. When you are done, press Back to save the new Roll Trim setting and return to the Radar Setup
Page.
5. Press Save from the Radar Setup Page. Press Cancel to exit without saving changes.
6. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.

5.9.3 RADAR Checkout

Perform a functional test of the RADAR system in accordance with manufacturers instructions. See the
MFD Pilot Guide for display operation.

5.9.4 RADAR Sensor Communications Troubleshooting

If there is a communication or data error between the RADAR sensor and the MFD, one of the
following messages will display on the bottom of the screen.

Table 25: Radar Sensor Error Messages

Message
Radar Sensor Data Is Invalid
Radar Sensor Has Failed
Radar Sensor Is Not Communicating
Invalid GPS Data and Radar is ON
Radar Automatic Standby Disabled
Meaning/Action
Data received from the RADAR sensor system can not be used by the
EX5000
Cycle power on the EX5000.
See RADAR Sensor Installation and User's Manual for troubleshooting
guidance.
The RADAR sensor system has reported an error.
Check R/T configuration module error log.
See the RADAR Sensor Installation and User's Manual for
troubleshooting guidance.
Communication of return data from the RADAR sensor to the MFD has
been lost.
Verify that the RADAR sensor is turned on and valid.
Verify that the EX5000 is properly seat in its tray.
Verify system wiring.
The RADAR is ON and the EX5000 has no ground speed data available
from the GPS/FMS.
Verify the GPS/FMS is ON and valid.
Verify system wiring.
See the RADAR Sensor Installation and User's Manual for
troubleshooting guidance.
The RADAR is ON, the EX5000 RADAR automatic standby mode is
disabled, and the EX5000 has no ground speed data available from the
GPS/FMS.
Verify the GPS/FMS is ON and valid.
Verify system wiring.
See the RADAR Sensor Installation and User's Manual for
troubleshooting guidance.