Table 5: Partial Function TSO
C147
C157
There are some functions performed by the MFD that are not covered by TSOs. It is the installer's
responsibility to ensure that when the MFD is installed it will meet the required minimum performance
standards for those functions. Those functions performed by the MFD but not covered by TSO are
listed in Table 10.
Table 11 below lists the TSO deviations that have been granted for the applicable TSOs.

Table 7: TSO Deviations

TSO
TSO-C43c -- Temperature
Instruments
TSO-C44c – Fuel Flow meters
TSO-C45b – Manifold Pressure
TSO-C47a – Fuel, Oil and Hydraulic
Pressure Instruments
TSO-C49b – Tachometer
TSO-C55a - Fuel and Oil Quantity
TSO-C63c -- Airborne Weather and
Ground Mapping Pulsed Radars
Display functions only
Airborne display functions only

Table 6: Functions Not Covered by TSO

Non-TSO Functions
Display of charts
Display of checklists
Lean assist function
Display of percent power
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in the TSO.
A digital readout is used instead of a dial.
Digits change from white to yellow or red when the parameter is in the
caution or warning range.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in AS407c.
Digits change from white to yellow or red when the parameter is in the
caution or warning range.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in the TSO.
Digits change from white to yellow or red when the parameter is in the
caution or warning range.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in AS408c.
Digits change from white to yellow or red when the parameter is in the
caution or warning range.
Graduations are every 100 RPM instead of every 50 RPM as would be
required by AS404b.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in AS404b.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in the TSO.
The MFD is environmentally qualified using the conditions and procedures of
DO-160E instead of those prescribed in the TSO.
- 10 -
EX5000 Installation Manual
P/N 600-00073 Rev 24