5.7 Traffic Sensor Setup

The EX5000 only supports the listed Traffic sensors. If a traffic sensor not on the
!
supported list is connected to the MFD some of the data may display but its accuracy
and traffic sensor control functions may be incorrect or inoperable. Display of traffic
sensor data is not a guaranty of correct traffic sensor installation and configuration.
The aircraft should be equipped with one of the following Traffic Sensors. Follow the setup instructions
for the appropriate sensor:
For TAS, see Section 5.7.1, "TAS (SkyWatch & Bendix/King) Setup" on page 47.
For TCAD, see Section 5.7.4, "TCAD Setup" on page 49.
For TIS, Section 5.7.7, "TIS Setup" on page 51.
If you need to switch between types of installed traffic sensors, first change the traffic sensor
Note:
type to None, press Save, and restart the EX5000. Then select the new traffic sensor type.
Table 20 describes the system configuration options (option availability depends on the EX5000
configuration ordered):

Table 20: Traffic Setup Configuration Options

System
Option
TAS
External Controller?
TCAD
Shields
(9900B
selected)
Range
Terminal
Standard
Enroute
Height
Terminal
Standard
Enroute
TIS-G
None
TCAD
TYPE
Values
Check/Clear
Check this box if a dedicated external Skywatch
controller is installed. With this box checked the
EX5000 does not initiate Skywatch standby or Self
Test functions.
Terminal
Standard
Enroute
0.5 – 1.5 nm
1 – 3 nm
2 – 15 nm
Limited to 6 nm max. by the 9900B sensor
200 – 1000 ft.
500 – 1500 ft.
1000 – 2000 ft.
9900B
9900BX
- 46 -