5.5.3 RS-232 Setup
If your GPS uses an RS-232 configuration, use Appendix J: Wiring Diagram – GPS/FMS for wiring
information.
An RS-232 interface does not provide for heading data from the GPS/FMS.
Note:
To set up the MFD for the RS-232 Interface:
1. From the Maintenance Mode Page, press GPS Setup. The GPS Setup Page displays.
2. Configure the interface as follows:
Receiver—Select the receiver-type for your GPS/FMS system. Determine the RS-232 output
format using Table 16, "GPS/FMS Manufacturer's Matrix," on page 39 or your GPS/FMS
Installation manual. Select one of the following RS-232 formats:
NMEA 0183
King/Aviation Format
Northstar Format
Port—Select RS232 1, or as wired.
Baud—Select the highest-possible baud rate for your GPS/FMS system. See the appropriate
GPS/FMS Installation manual or see Table 16, "GPS/FMS Manufacturer's Matrix," on page 39
to determine for the maximum speed. The following speeds are available: 1200, 2400, 4800,
9600, 19200, or 38400.
3. When you are done, press Save. Press Cancel to exit without saving changes.
4. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.