Figure 18: Radar Setup Page - Avidyne Entegra EX5000 MFD Series Installation Manual

Table of Contents

Advertisement

EX5000 Installation Manual
P/N 600-00073 Rev 24
Bendix/King Installation Manual Replacement Section 2
2.4.4.1 Stabilization Calibration with Radar Indicator
To calibrate the radar pitch and roll:
A. From the Aux Page, enter Maintenance Mode, as described in Section 5.4, "Using the
Maintenance Mode Page" on page 33. Select Radar Setup to display the Radar Setup Page:
Once the ART-2000 has been installed, the Radar Setup Page will be similar to the Page
Note:
shown here.
B. Set Park position to Full up.
C. Ensure that Enable Automatic Standby is selected.
D. Restart the MFD, and open the Radar Page.
E. From the Radar Page:
Press Radar Standby until the GND setting reads STBY.
Set Mode to GND. The Knob button will display in the lower left corner.
Set Knob to Gain.
Use the Gain knob (outer left) to reduce the gain until the Gain indicator in the upper right
shows the minimum setting. Note that you need to turn the Gain knob clockwise to reduce the
gain (and counter-clockwise to increase it).

Figure 18: Radar Setup Page