5.8 TAWS Setup (Optional)
The MFD can interface to the Honeywell Bendix/King EGPWS systems with Phase 2 or later software.
5.8.1 TAWS Setup
➤
To configure the TAWS interface:
1. From the Maintenance Mode Page, select TAWS Setup. The TAWS Setup Page displays:
2. Set the following options:
■
Sensor—Honeywell EGPWS
■
ARINC 429 Port—ARINC 429 4 – TAWS Default
■
ARINC 453 Port—ARINC 453 2 – TAWS Default
■
Altitude Annunciation On—Select this feature to permit a visual annunciation of GPS
altitude on the TAWS display. If selected, a checkmark displays.
3. When you are done, press Save. Press Cancel to exit without saving changes.
4. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System.
Figure 16: TAWS Sensor Setup Page