Tas (Skywatch) Checkout; Tas (Bendix/King) Checkout - Avidyne Entegra EX5000 MFD Series Installation Manual

Table of Contents

Advertisement

5.7.2 TAS (SkyWatch) Checkout

For TAS (SkyWatch), Self Test can only be performed from STANDBY mode and will return to
STANDBY mode upon successful completion of the Self Test.
To perform a Self Test:
1. With Traffic in Stand By, rotate the left knob and select the Setup Page.
2. Select Traffic Self Test. The following actions occur:
The Map Page displays.
The Sensor Status indicates that the sensor is in "Test" and a Traffic test pattern appears on
the display.
If the Self Test fails, an error message is generated and displayed on the MFD screen. See the
SKY497 Installation Manual for explanations and fault isolation procedures.
To test the Sky497 installation:
1. Use the alternate display procedure described in Appendix E of the SKY497 Installation Manual. A
terminal device using a RS-232 serial data cable is needed for these setup procedures.
2. See Appendix D in the SKY497 Installation Manual for information about configuring the terminal
device. Any computer with RS-232 terminal emulation software (e.g., Procomm, HyperTerminal,
etc.) may be used as the terminal device.

5.7.3 TAS (Bendix/King) Checkout

To test the TAS (Bendix/King) installation, verify correct communication by monitoring the Message
List on the Setup page for the following message: "Traffic Sensor Operating Normally".
The MFD does not command the KTA870 in Self Test mode. Use the KTA870 control panel if
Note:
installed. See the KTA870 Installation Manual for fault isolation procedures.
- 48 -
EX5000 Installation Manual
P/N 600-00073 Rev 24

Advertisement

Table of Contents
loading

Table of Contents