Tcad Dual Display Setup; Tcad Checkout; Table 21: Tcad Shield Settings - Avidyne Entegra EX5000 MFD Series Installation Manual

Table of Contents

Advertisement

Range—Sets the horizontal range of the shield. The range is in nautical miles and can be set
for a value between 0.0 and 10nm, in 0.1nm increments
Height—Sets the vertical distance in feet with a value between 0 and 5000 ft. in 100 ft.
increments
3. Select each shield you want to configure from the Shield drop down menu.
4. Select the Range and Height for that shield from the drop-down lists.
Table 21 provides the suggested minimum and maximum values for the range and height of each
shield.

Table 21: TCAD Shield Settings

Terminal
Standard
Enroute
The Max range values shown above are the largest values that the TCAD processor will
Note:
accept. Choosing larger values than those shown will cause the processor to default to smaller
shield sizes and is not recommended.
5. When you are done, press Save. Press Cancel to exit without saving changes.
6. Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press Restart System. If needed, see Table 22, "Traffic Messages," on page 52.

5.7.5 TCAD Dual Display Setup

When installing the MFD with an Avidyne TAS600 9900BX display unit, see the Avidyne TAS600
Series Installation Manual for wiring procedures. See Figure 2-15 Wiring Diagram for Dual Displays
and Section 7 in the Ryan manual for instructions.\

5.7.6 TCAD Checkout

The MFD does not display the TCAD Self Test function. To perform this test, use the Avidyne TAS600
display unit.
On installations with the TCAD 9900 display unit, follow the checkout procedures shown in the
Avidyne TAS600 Series Installation Manual.
On installations without the TCAD 9900 display unit (MFD only), follow the checkout procedures
shown in the Avidyne TAS600 Series Installation Manual with the exception of the display test.
Range (NM: 0.5)
Min
0.5
1.5
1.0
3.0
2.0
6.0
- 50 -
Height (feet: 100)
Max
Min
200
500
1000
EX5000 Installation Manual
P/N 600-00073 Rev 24
Max
1000
1500
2000