Toro Reelmaster 5410 Series Service Manual page 43

Models with infocenter display
Hide thumbs Also See for Reelmaster 5410 Series:
Table of Contents

Advertisement

g229072
1.
Air cleaner assembly
2.
Mounting band
3.
Hex nut
4.
Shoulder bolt
5.
Spring
6.
Service indicator
Removing the Air Cleaner Assembly
Installing the Air Cleaner Assembly
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
Reelmaster 5610
7.
Adapter
8.
Inlet hose
9.
Hose clamp
10.
Air cleaner hose
11.
Flange nut
12.
Flange-head screw
Note: Reelmaster 5010 series machines with a Kubota diesel engine have very
similar air cleaner assemblies. Reelmaster 5410 and 5510 machines use the
same air cleaner assembly
different air cleaner assembly
1. Park machine on a level surface, lower cutting units, stop engine, engage
parking brake and remove key from the key switch. Raise and support hood.
2. Remove air cleaner components as necessary
3. Refer to Traction Unit Operator's Manual for air cleaner service and
maintenance procedures.
Any leaks in the air filter system will allow dirt into engine and
will cause serious engine damage. Ensure that the all air cleaner
components are in good condition and are properly secured during
assembly.
Figure 12
13.
14.
15.
16.
(Figure
11). Reelmaster 5610 machines use a slightly
(Figure
12).
IMPORTANT
Page 3–9
Air cleaner bracket
Bolt
Mount bracket
Hose clamp
(Figure 11
or
Figure
Kubota Diesel Engine: Service and Repairs