Piston (Traction) Pump Flow Test (Using Tester with Flow Meter and
Pressure Gauge) (5410/5410-G/5410-D/5510/5510-G/5510-D/5610)
g230022
Test Procedure
Reelmaster
®
5410/5510/5610 Series
15216SL Rev C
This test measures piston (traction) pump output (flow). During this test, pump
load is created at the flow meter using the adjustable load valve on the tester.
Traction circuit flow for your Reelmaster is approximately 114
L/minute (30 gallons/minute). Use 150 L/minute (40 gallons/minute)
hydraulic Tester #AT40002 (pressure and flow) for this test; refer to
Special Tools (page
1. Park machine on a level surface with the cutting units lowered and off. Shut
off engine. Ensure that the mow speed limiter is in the transport position to
allow full movement of traction pedal.
Figure 91
IMPORTANT
6–44).