Functions Of Switches And Points On Pwb-I; Pwb-I Location; Tech. Rep. Settings Switches Board Pwb-I - Minolta EP5000 General, Mechanical/Electrical

Hide thumbs Also See for EP5000:
Table of Contents

Advertisement

Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
1151SBS0300A
3

FUNCTIONS OF SWITCHES AND POINTS ON PWB-I

1151SBS0301A

3-1. PWB-I Location

1156SBS0302A

3-2. Tech. Rep. Settings Switches Board PWB-I

Symbol
Name
Trouble Reset Switch
S1
Initialize Switch
PJ2
TP1
GND Test Point
Memory Clear Test Point
TP3
1149S002BB
Description
Resets a malfunction including those of the Exposure
Lamp (C04XX) and fusing (C05xx).
Forcibly resets a misfeed or malfunction that occurrs
due to incorrect operation, etc. when it cannot be reset
by opening and closing the Front Door or the press of
S1.
Ground terminal used for memory clear.
Initializes all data except the counts of electronic count-
ers, access numbers and administrator number for Copy
Track, and RD mode functions.
S-5
1156S001AA