5. I/O Check
D This function is used to check the sensors and boards when a paper misfeed or malfunction occurs,
thereby locating the fault.
Touch Panel
Display
IC Port Data Check
Shows the states of the I/O ports when the copier is in stand-by. With the
output ports, the change of the data in the port allows an operation check of
electrical components to be performed.
Paper Path Sensors
A sheet of paper is fed through the copier to switch the state of sensors along
Check
the paper path between 1 and 0, thereby determining whether the sensors are
operational or faulty.
<Procedure>
1. Select the paper path (paper source, copying mode, etc.) to be checked and
enter this function.
2. Press the Start key to start the sensor check sequence.
Note: The sensor detects paper when "0" and no paper when "1".
Tech. Rep. Mode " I/O Check
Operation
NOTE
For details, see TROUBLESHOOTING.
No.
Display
1
1st Feed
1st Drawer Paper Take-up Sensor PC56
2
2nd Feed
2nd Drawer Paper Take-up Sensor PC57
3
3rd Feed
3rd Drawer Paper Take-up Sensor PC21
4
4th Feed
4th Drawer Paper Take-up Sensor PC29
5
1st Vertical
1st Drawer Vertical Transport Sensor PC63
6
2nd Vertical
2nd Drawer Vertical Transport Sensor PC64
7
3rd Vertical
Vertical Transport Sensor 3 PC17
8
4th Vertical
Vertical Transport Sensor 4 PC22
9
Trans. Roller
Transport Roller Sensor PC54
10
Leading Edge
Paper Leading Edge Detecting Sensor PC55
11
1st Exit
Paper Exit Sensor S53
12
2nd Exit
13
Turnover Up
Duplex Unit Vertical Transport Sensor 1 PC30
14
Turnover Low
Duplex Unit Turnover Path Sensor PC13
15
Dup Entrance
Duplex Unit Paper Entry Sensor PC14
16
Dup Exit
Duplex Unit Paper Take-Up Sensor PC16
17
Non Sort
Non-Sort Exit Sensor PC1
18
Sort
Sort Exit Sensor PC2
19
Punch Regist
Punch Registration Sensor PC10
S-32