Minolta EP5000 General, Mechanical/Electrical page 230

Hide thumbs Also See for EP5000:
Table of Contents

Advertisement

Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
<Clearing Procedures>
D Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ2.
4. Check that the message "Initialize completed" is shown on the Touch Panel, then touch "Enter."
D Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP1 and 3.
4. Check that the message "Memory Clear completed" is shown on the Touch Panel, then touch "Enter."
NOTE
D If an erratic operation or display occurs, perform the clearing procedures in the order of PJ2 and TP3.
D When memory clear has been performed, make the necessary settings again.
Clearing Method
Data Cleared
Misfeed display
Malfunction display (except
Exposure Lamp and fusing
system)
Malfunction display (all includ-
ing Exposure Lamp and fusing
system)
Erratic operation/display
User mode
Service mode
F5/F7 setting values
System Input
Accessory Test
Level History
Adjust mode
f : Cleared (initialized)
<List of Data Cleared by Switches and Points>
Trouble Reset
Front Door
Switch
Open/Close
(S1)
f
f
f
f
*
f
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*: Not cleared:
S-6
Initialize
Memory Clear
Switch
Test Point
(PJ2)
(TP3)
f
f
f
f
f
f
f
f
*
f
*
f
*
f
*
f
*
f
*
f
*
f

Hide quick links: