Interleaf EP5000/EP4000 DIS/REASSEMBLY, ADJUSTMENT
97.04.01
(10) Removal of the Suction Unit
1.
Remove the 1st and 2nd Drawers.
2.
Swing down the Front Door and slide out the IU.
3.
Remove the Paper Dust Remover Assy.
4.
Remove the Fusing Unit.
1156D029AA
1156D030AA
1156D031AA
5.
Remove the motor cover.
6.
Unplug two connectors from the lower end of the Suction
Unit.
7.
Swing the Transport Section Release Lever back to its
original position.
8.
Pressing down the Image Transfer/Paper Separator Coro-
nas Unit, pull it out of the copier.