Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
uAD-9 Storage Misfeed Clearing Procedure
Symptom
Step
The leading edge of
1
the paper is station-
ary inside the Du-
plex Unit.
2
3
Paper is stationary
at the storage sec-
tion.
1
Check Item
Result
Is the Paper Guide Mylar
dirty or deformed?
Does PC14 operate proper-
ly? Using the IC Port Data
Check function, make an in-
put port check on PWB-A
(Dup) (IC1G) PC1.
Does SL31 operate proper-
ly?
Using the IC Port Data
Check function, set the data
of PWB-A (Dup) (IC1G)
PH1 to "0."
Does PC15 operate proper-
ly?
Using the IC Port Data
Check function, make an in-
put port check of PWB-A
(Dup) (IC1G) C2.
T-40
Action
Clean or change the mylar.
YES
Change PWB-G, PWB-A
YES
(copier), or PWB-A
(PF-205/105).
Check the PC14 actuator
for operation and, if it oper-
NO
ates properly, change
PC14.
Check the Gate Switching
YES
Lever for operation.
Change PWB-G, PWB-A
(copier), or PWB-A
NO
(PF-205/105). Change
SL31.
Change PWB-G, PWB-A
YES
(copier), or PWB-A
(PF-205/105).
Check the PC15 actuator
for operation and, if it oper-
NO
ates properly, change
PC15.