Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
1156SBM1307A

13-7. Sub Hopper Toner Empty Detection Control

D A toner-empty condition in the Sub Hopper is detected by the magnet fitted to the
Sub Hopper Toner Empty Detecting Lever and Sub Hopper Toner Empty Switch
S106.
D The Sub Hopper Toner Empty Detecting Lever rides on the eccentric cam fitted to
the rear of the Sub Hopper Toner Agitating Lever. It is moved up and down as the
eccentric cam is turned by the drive transmitted from Main Drive Motor M1.
D While the amount of toner in the Sub Hopper is higher than the predetermined level,
the Sub Hopper Toner Empty Detecting Lever rests on the toner and does not make
the up-and -down motion. S106 therefore remains deactuated.
D When the amount of toner in the Sub Hopper is lower than the predetermined level,
the Sub Hopper Toner Empty Detecting Lever moves up and down by the eccentric
cam. This result in S106 being actuated and deactuated. When the time S106 is
actuated exceeds a predetermined value, the copier CPU determines that the Sub
Hopper has run out of toner.
Magnet
Sub Hopper Toner
Empty Switch S106
Toner Empty
Controlled Part
Sub Hopper Toner Empty Switch S106
1134M015AA
1134M016AA
Control Signal
PJ11A-8B
M-45
Sub Hopper Toner
Empty Detecting
Lever
Eccentric Cam
Toner Full
1134M017AA
WIRING DIA-
ON
OFF
GRAM
L
H
2-L