Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
uC0610
Step
Check Item
Are all connectors on PWB-F, M6, and
1
PC90 plugged in securely?
Does the voltage across PWB-F
2
PJ6F-5 and GND change from DC5V
to DC0V when PC90 is blocked?
Is the Lens drive defective?
3
uC0620
Step
Check Item
Are all connectors on PWB-F, M7, and
1
PC86 plugged in securely?
Does the voltage across PWB-F
PJ6F-2 and GND change from DC5V
2
to DC0V when PC86 is blocked?
Is the Mirror drive defective?
3
Result
Plug them in securely.
NO
Change PC90.
NO
YES
Correct or change the defective part.
NO
Change PWB-F or M6.
Result
Plug them in securely.
NO
Change PC86.
NO
YES
Correct or change the defective part.
NO
Change PWB-F or M7.