Interleaf EP5000/EP4000 TROUBLESHOOTING
97.04.01
Step
Check Item
Does the voltage across PWB-A
1
PJ8A-13 and GND become DC0V (L)
when the Start key is pressed?
Perform the "Controller Board Check."
Is malfunction code "C0312" or
2
"C033B" displayed?
Disconnect CN7. Is there continuity
3
across CN7-1 and -2 on LA1 side?
Is the voltage across PJ3J-1 and –3 on
4
PWB-J the source voltage?
Is the voltage across PWB-A PJ3A-2
and GND 3.9V or less when LA1 is off,
5
the Scanner is at the home position,
and the Original Cover is lowered?
Result
Go to step 2.
YES
Change PWB-A.
YES
Change LA1 or TF1.
NO
YES
Change PWB-J.
NO
Check the power supply line.
Change PWB-A.
YES
Change PWB-H.
NO
T-70
Action