Make sure the battery is good and installed correctly.
Check for interference from metal objects. Move or rotate the sensor.
Move the sensor to a new location.
If a door or window is closed, but the panel announces it is open:
Be certain the arrow on the magnet and the guide line on the transmitter are
aligned and within ¼ inch of each other.
The sensor tamper switch may be open (cover off).
If a motion sensor goes off continuously, be sure the sensor is mounted on a
solid surface and the viewing field is free from sources of changing temperature.
If a motion sensor does not respond to motion:
Make sure the sensor battery is good and installed correctly. Wait 2 minutes
after installing a new battery to test the sensor.
Adjust the sensor mounting.
Leave the area for 3 minutes, then retest.
The environment may be too hot or too cold. Outdoor sensors operate
between 32 and 120ºF (0 and 49ºC).
Dirt or dust may be causing the problem. Wipe the sensor with a clean, damp
cloth.

Specifications

Power
Radio frequency
Storage temperature
Operating temperature
Maximum humidity
Auxiliary power
Size (LxWxD)
Simon XT Installation Manual
9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid. The battery will last
24 hours with no AC and specified standby load of 250 mA. Maximum
battery charging current is 45 mA. With loss of AC, panel will continue to
operate normally to a minimum of 5.1 VDC.
319.5 MHz
-29 to 140ºF (-34 to 60ºC)
32 to 120ºF (0 to 49ºC)
85% relative humidity, noncondensing
Unregulated 5.3 to 12.3 VDC, with a maximum of 250 mA
7 x 5.75 x 2.125 in. (178 x 146 x 54 mm)