UL Canada listed installations

This section describes the requirements for CUL (UL Canada) listed installations.
Canadian standards CSA certified accessories
Standard Class 2, 9 VAC, 3.34 A power transformer (UTC Fire & Security model
22-153-CN).
Residential burglary alarm system unit (ORD-C1023-1974)
Basic system as described for UL 1023 listed installations plus:
Hardwired magnetic contact (13-068 or 13-071) or wireless learn mode
door/window sensor (60-670)
Siren timeout set to six minutes or more
Residential fire warning system control unit (ULC-S545-M89)
Basic system as described for UL 985 listed installations plus:
Wireless smoke sensor 60-848-95 learned into sensor group 26
Siren timeout set to six minutes or more
For 24-hour backup, the total current draw for all connected devices is limited
to 250 mA (during normal standby conditions) using a 1.2 AH battery.

California state fire marshal listed installations

Applied for.

Opening panel cover and chassis

Tabs at the top of the panel secure and release the front cover and the chassis.
The plastic hinges on the panel bottom allow the cover and chassis to swing
down and out of the way (Figure 3 on page 21).
20
Simon XT Installation Manual