Simon XT/XTi GSM Module V4 Installation
Instructions
Content
Contact information#1
Introduction#1
Compatibility#1
Account creation#1
Installation#2
Power up#3
GSM phone test (module registration)#3
Control panel settings that change automatically with
HSPA 3G module#3
Troubleshooting: Module Status Information#3
Troubleshooting: LEDs#4
LED patterns for the various module states (modes)#6
Improving wireless signal strength#6
Interactive menus#6
Walking customer through new user setup on the web#9
Specifications#10
Regulatory information#10
Contact information
www.utcfireandsecurity.com
or
For customer support, see
www.interlogix.com/customer-
support
© 2013 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a unit of
United Technologies Corporation. All rights reserved.
For additional information and support on Alarm.com products
and services, please visit
www.alarm.com/dealer
Alarm.com technical support at 1-866-834-0470.
Copyright © 2013 Alarm.com. All rights reserved.
Introduction
The HSPA 3G module (part numbers 600-1048-XT-ZX-TM ,
600-1048-XT-ZX-AT AND 600-1048-XT-ZX-RG) for Simon XT
and XTi enables wireless reporting of all alarms and other
system events from the Simon XT and XTi control panels using
an all-digital, HSPA wireless (cellular) network. The module
can be used as the primary communication path for all alarm
P/N 466-2461 • REV H • 29JUL13
www.interlogix.com
or contact
signaling, or as a backup to a telephone line connection to the
central monitoring station. The wireless alarm signaling and
routing service is operated by Alarm.com. The V4 module also
features integrated support for Alarm.com's emPower
solution with built-in Z-Wave capabilities.
The module interfaces with the Simon XT and XTi panel
boards, fits into a special compartment inside the panel, and is
powered by the control panel and panel battery.
Compatibility
The V4 module with firmware version 151 & up is compatible
with Simon XT and XTi panels. Older versions of the
Alarm.com module, including versions of the V4 module with
previous firmware versions are not compatible with the Simon
XTi.
Account creation
Before installing an Alarm.com HSPA 3G Module in a Simon
XT or XTi system, a new customer account needs to be
created with Alarm.com. We recommend creating the account
at least 24 hours in advance of installation to ensure that the
radio is activated prior to installation.
To activate an account go to www.alarm.com/dealer and login.
Under the "Customers" heading at the top left of the page click
on "Create New Customer". You will need the following
customer information to create the account:
Customer Name
Customer Address
Customer Phone Number
Customer E-mail
Preferred login name for the customer
Alarm.com Radio Serial Number
At the end of the account creation process you will be able to
print a Welcome Letter for the customer that has their login
information and temporary password for the Alarm.com
website.
TM
1

Advertisement

loading

Summary of Contents for Interlogix Simon XT

  • Page 1 © 2013 UTC Fire & Security Americas Corporation, Inc. Under the “Customers” heading at the top left of the page click Interlogix is part of UTC Climate Controls & Security, a unit of on “Create New Customer”. You will need the following United Technologies Corporation.
  • Page 2 Figure 1: Top view Simon XT and XTi panels Installation Installation consists of inserting the module into the panel, attaching the antenna, and performing a GSM phone test at the panel. Follow these guidelines during installation: • Before affixing the panel to a wall, verify the HSPA signal level at the installation location.
  • Page 3 The Simon XT/XTi panel will let you know when the GSM Phone Test has completed by displaying “GSM Test signal sent OK” on the panel screen. This indicates that Alarm.com Power up has received and acknowledged the signal.
  • Page 4 In addition, some of the information can be retrieved on the flashes in patterns to indicate Z-Wave status. Simon XT via long key presses from the keypad. Press and GSM Communication. Flashes every time the GSM signal level hold the following panel keys for 10 seconds to display the is checked and when packets are exchanged with Alarm.com.
  • Page 5 Devices cannot operation of the module. be added to a network if they are already a part of a In connected mode, the LED toggles on and off. network Simon XT/XTi GSM Module V4 Installation Instructions...
  • Page 6 Idle Mode and update the signal level reading. The system will go into Idle Mode every 2 hours to check for any incoming Simon XT panels version 1.3 and up with GSM module v150 & messages. up or XTi panels with GSM module v151 & up have a special set of “Interactive Services”...
  • Page 7 Make sure the device you are trying to add is powered up and within 3 to 6 -- GSM Module Status See Installer Programming section feet of the Simon XT or XTi panel. above. Refer to the manufacturer’s -- Z-Wave Setup...
  • Page 8 Note: With the GSM module installed, the total current available from the Simon XT HW1&2 DC out terminal is 50 mA at up to 120°F (49°C). --- Remove Device Remove an existing Z-Wave device, or to “reset”...
  • Page 9 At least one phone number and e-mail address where ---Update 2WTTS Press Update 2WTTS to force an notifications can be sent update of the thermostat, lights or locks information shown on the touch Simon XT/XTi GSM Module V4 Installation Instructions...
  • Page 10 (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the Simon XT/XTi GSM Module V4 Installation Instructions...

This manual is also suitable for: