Xgen Specifications; Mains Power Specifications; Power Supply Specifications; General Features - Interlogix xgen Installation & Programming Manual

Table of Contents

Advertisement

xGen Specifications

Mains power specifications

Mains input voltage
Current consumption at 230 VAC:
NXG-64
Transformer output:
NXG-64

Power supply specifications

Power supply type
Power supply voltage
Power supply current
NXG-64
Main board consumption
NXG-64
Maximum system current available
NXG-64
Auxiliary power output (AUX. POWER)
Battery power output (BAT)
Battery type
Maximum voltage at power supply, auxiliary
power output and battery power output
Battery low condition
Battery disconnect voltage
Maximum ripple voltage V, p-p

General features

Code combinations
End-of-line resistor
Onboard zones
Maximum zone number:
NXG-64(IP)
NXG-256IP
NXG-512IP
Additional inputs
xGen Installation & Programming Guide
230 VAC +10%, −15%, 50 Hz ±10%
180 mA max.
16.3 VAC, 40 VA
EN50131-6 Type A
for indoor use inside the supervised premises
13.8 VDC +/- 0.3 V
1.45 A max. at 13.8 VDC +/- 0.3 V
100 mA at 13.8 VDC +/- 0.3 V
1350 mA at 13.8 VDC +/- 0.3 V
13.8 VDC +/- 0.2 V, 1 A max.
13.8 VDC +/- 0.2 V, 400 mA max.
Lead acid rechargeable
BS127N: 7.2 Ah 12 V nominal
BS130N: 12 Ah 12 V nominal
BS131N: 18 Ah 12 V nominal
14.5 VDC
From 10.0 VDC to 11.0 VDC
10.0 VDC
200 mV typical, 400 mV max.
From 10,000 (4 digits) to 100,000,000 (8 digits)
680 Ω, 3.3 kΩ (default), 3.74 kΩ, 6.98 kΩ
8 (default); 16 if zone doubling enabled.
64
256
512
2 - box tamper
19

Hide quick links:

Advertisement

Table of Contents