Keyfob: Press the Light button repeatedly to turn all lights on and off. The
panel responds with Lights on/off.
Remote handheld touchpad: Press the Lights on button and the unit
number of the lamp module using the numeric buttons to test individual lamp
modules 1 through 8. The panel responds with Light # on/off. Pressing the
Lights on or Lights off button twice turns all the lights on or off.
X10 siren and lamp module functions
All sirens turn off when the system is disarmed or when the siren timeout expires.
Siren priority is fire (highest priority), intrusion, and emergency. Table 33
identifies the light information for each of these siren types.
Table 33: Alarm siren and X10 light information
X10 lights
X10 siren
Interior and panel siren Temporal 3
If an alarm of greater priority occurs during an alarm of lower priority, the greater
priority alarm sirens sound. Fire alarms sound a temporal 3 pattern (0.5 seconds
on, 0.5 seconds off for three beeps then 1.5 seconds off).
Note: The X10 siren must be set to unit #9 to "hear" emergency alarms and
status beeps. To hear emergency alarms only, set to unit #10.
Simon XT Installation Manual
Fire
Steady
Steady
Intrusion
Flashing
Steady
Steady
below
Emergency
Steady
Alarm beeps
Fast on/off
63