Programming
This section describes the basic steps for adding the sensor
to panel memory. For complete instructions, refer to the
specific panel's documentation.
To program the sensor:
1.
Set the panel in program mode.
2.
When prompted by the panel, enter the appropriate
group number (groups 00 through 07).
Note: For UL installations where the holder is used, the
sensor must be added as a fixed type (sensor groups
00, 02, 04, or 05).
3.
When prompted by the panel, select the desired sensor
number.
4.
When prompted by the panel, trip the sensor by
pressing the sensor button.
5.
Exit from program mode.

Sensor Test

To test the sensor:
1.
Set the system to the Dealer Sensor Test mode.
2.
Press the button on the sensor.
3.
Count the number of signals received by the panel,
indicated by interior siren beeps. Seven to eight beeps
are considered acceptable.
4.
Test the sensor from several locations within the
premises to check for consistent response.

Battery Replacement

To replace the sensor battery:
1.
To disassemble the sensor, remove the two screws on
the back of the sensor and separate the front and back
plastic.
Caution: You must be free of static electricity before
handling the transmitter circuit board. Touch a
grounded, bare metal surface before touching the
circuit board, or wear a grounding strap.
2.
Remove the old battery from its holder and install the
new battery, observing polarity.
Caution: Install only the same size and type of battery. Do
not substitute another size or type of battery.
3.
Reassemble the sensor.
Note: Be sure to assemble the sensor correctly to ensure
water resistance. Be especially careful not to nick or
damage the rubber gasket lining.
Test the sensor as described in "Sensor Test" above.
4.
2 / 2
Lithium Battery Disposal
Lithium batteries that are no longer usable are considered
hazardous waste. Be sure to properly dispose of the old
battery. Contact your local city government for hazardous
waste disposal laws.

Specifications

Compatibility
All Interlogix Security Learn Mode panels
Power source
3.6 VDC Saft or Tekcell lithium battery
Enclosure
Water-resistant and shock-resistant
Dimensions (LxWxD)
2.25" x 1.75" x 0.75" (57.1 mm x 44.4 mm x
19 mm)

Regulatory Information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
2995 Red Hill Ave, Costa Mesa, CA 92626 USA
FCC / IC
This device complies with part 15 of the FCC
compliance
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by Interlogix can void the user's authority to
operate the equipment.
FCC ID: B4Z-697B1-PANIC
IC ID: 1175C-697B1PANIC
This device complies with Industry Canada
license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this
device may not cause interference, and (2) this
device must accept any interference, including
interference that may cause undesired operation
of the device.
Cet appareil est conforme aux normes RSS
exemptes de licence d'Industrie Canada.
Le fonctionnement est soumis aux deux
conditions suivantes : (1) cet appareil peut ne pas
provoquer d'interférences et (2) cet appareil doit
accepter toutes interférences, y compris les
interférences pouvant provoquer un
fonctionnement non désiré de l'appareil.
U.S. patents
4,855,713, 4,864,636, and others pending.
www.utcfireandsecurity.com
For customer support, see
© 2018 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a unit
of United Technologies Corporation. All rights reserved.

Contact information

or
www.interlogix.com
www.interlogix.com/customer-support
May 7, 2018
P/N 46-667 • REV K • 27APRIL18

Advertisement

loading