Download Print this page

Interlogix ADC-IS-300-LP-BX Installation Manual

Image sensor

Advertisement

Quick Links

Interlogix Simon XT Image Sensor Version 3 - Installation Guide
Notice: Newly manufactured Interlogix Simon XT/XTi/XTi-5 modules will no longer support the Image Sensor effective in
June 2022. These new modules can be identified by Rev. G on the product label or verify if the Image Sensor radio is
built-in. For more information about verifying, see
modules in the field will continue to support the Image Sensor.
This guide contains instructions for installing an Image Sensor Version 3 (ADC-IS-300-LP) on an Interlogix Simon XT
panel.
Product summary and technical specifications
The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in camera designed to capture
images during alarm or non-alarm events when motion is detected.
Product features:
• Communicates wirelessly to the security control panel
• 35 foot detection range with a 90 degree horizontal FOV
• Configurable PIR sensitivity and pet immunity settings
• Image: VGA 640x480 pixels
• Color Images (except in night vision)
• Night vision image capture with infrared flash (black & white)
• Tamper detection, walk test mode, supervision
• All systems can support up to three Image Sensors
• UL 639 certified
https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim...
Verify which radios are built in to an Alarm.com
module. All existing
Updated: Fri, 10 Mar 2023 20:24:24 GMT
1

Advertisement

loading

Summary of Contents for Interlogix ADC-IS-300-LP-BX

  • Page 1 Verify which radios are built in to an Alarm.com module. All existing modules in the field will continue to support the Image Sensor. This guide contains instructions for installing an Image Sensor Version 3 (ADC-IS-300-LP) on an Interlogix Simon XT panel. Product summary and technical specifications The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in camera designed to capture images during alarm or non-alarm events when motion is detected.
  • Page 2: Technical Specifications

    • Recommended Mounting Height and Angle: Refer to the Recommended Install Height and Angle Table • Motion Profiles & Sensor Range: Refer to the PIR Sensitivity Settings Table Hardware compatibility requirements Security control panel Interlogix Simon XT version 1.3+ Alarm.com module Simon XT Module with firmware 146+ https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim…...
  • Page 3 Requires Image Sensor Daughterboard for modules with firmware 185 or lower. Compatible with all daughterboard versions. Note: The Image Sensor radio is built into modules with firmware versions 187+, so modules with this firmware Extra required hardware do not require a separate Image Sensor daughterboard to be installed.
  • Page 4 Install alarm hardwire inside control panel For Simon XT panels, connect the daughterboard alarm wire. When using the Simon XT panel, it is required to connect the included blue alarm wire from the HW hardwire output located on the daughterboard (use HW, do not use C) to the HW2 IN (terminal 3) slot on the Simon XT panel to enable local alarm activations.
  • Page 5 Alarm.com. For information about performing a communication test, see Send a communication test from an Interlogix Simon Installation: Enrolling Image Sensor to panel Image Sensors can be enrolled remotely using the Partner Portal or MobileTech app, or locally using the panel. For https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim…...
  • Page 6 Image Sensors remotely, see Enroll an Image Sensor on an Interlogix Simon To enroll the Image Sensor locally on a Simon XT: Important: For smoothest installation, learn in one Image Sensor at a time. Insert batteries only after initiating learn mode at the panel.
  • Page 7 Pet Immunity Larger Rooms Smaller Rooms Intended Operation Mounting Height 6 Feet 8 Feet 8 Feet Angle Shallow, 6° Shallow, 6° Deep, 18° Teeth Down Teeth Up Teeth Up Bracket Orientation 15 to 20 ft. Coverage Distance 30 to 35 ft. 30 to 35 ft.
  • Page 8 Don't ▪ Set sensor on a flat surface. ▪ Center the target capture area in the middle of ▪ Set sensor across from mirrors or reflective the frame. surfaces. ▪ Enroll and install within 100 ft. of panel. ▪ Face sensor toward or close to areas that have Installation site conditions can reduce range metallic objects or electronics (to avoid considerably.
  • Page 9 7. Set the PIR Sensitivity Settings using the panel or remotely using the Partner Portal or MobileTech app. For information about setting the PIR Sensitivity Settings, see Change Image Sensor sensitivity. The following three options can be set: Normal Default setting More sensitive motion profile with potential higher risk High of false alarm.
  • Page 10 Other feature compatibility Simon XT 2WTTS compatibility When using a Two Way Talking Touchscreen with the Simon XT panel, Image Sensor activity is not reported or visible on the touchscreen, except in alarms. When alarms are tripped on an enrolled Image Sensor, the alarms are reported and displayed on the 2WTTS through the sensor 39 hardwire zone.
  • Page 11: Trouble Conditions

    Tamper A built-in accelerometer detects movement or repositioning of the Image Sensor and will initiate a tamper whenever a change in sensor orientation is detected. The tamper automatically clears after the sensor is returned to the upright position and no movement has been detected for 5 minutes. A tamper can also be cleared by resetting the sensor. Trouble conditions By default, trouble conditions (malfunction, tamper &...
  • Page 12 To replace the sensor batteries, slide the front of the sensor up off the sensor-back. Dispose of used batteries per the battery manufacturer instructions and following local regulations. Replacing batteries https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim… Updated: Fri, 10 Mar 2023 20:24:24 GMT...
  • Page 13 Image Sensor LED reference chart https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim… Updated: Fri, 10 Mar 2023 20:24:24 GMT...
  • Page 14 Resetting the Image Sensor There are two ways to reset the Image Sensor. https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim… Updated: Fri, 10 Mar 2023 20:24:24 GMT...
  • Page 15 Power Cycle If you have issues connecting the Image Sensor to the account, power cycle the Image Sensor in one of two ways: • Take out and reinsert the batteries, or • Use a paperclip to quickly press and release the Sensor Reset button. Only press the reset button if the LED has been off for at least 10 seconds and the panel is not in Add mode.
  • Page 16 Deleting Image Sensor from panel Instructions on how to properly delete and Image Sensor from a system. It is important to do the steps in order. 1. Delete the Image Sensor from the account using the panel’s Interactive Services, Partner Portal, or MobileTech app.
  • Page 17 PIR lens and camera coverage diagrams Figure 3. Side View: PIR Lens Coverage https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Image_Sensor/Image_Sensor_Version_3/Interlogix_Sim… Updated: Fri, 10 Mar 2023 20:24:24 GMT...
  • Page 18: General Troubleshooting Steps

    Figure 4. Top View: PIR Lens Coverage As indicated in Figure 4, the camera coverage area is narrower than the PIR coverage area. When installing, mount sensor where subjects are likely to be centered in or across PIR and camera field of view. Troubleshooting General troubleshooting steps •...
  • Page 19: Regulatory Information

    system or daughterboard, delete the sensor from the system and hold the sensor reset button for 10 seconds to clear the sensor from the old network before attempting to enroll the sensor in a new network. The sensor cannot be cleared if it is currently communicating with its network. In this case, the sensor must be deleted from the system first through the control panel or remote command.
  • Page 20 • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different form that which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules.