Sensors - Interlogix Simon XT Installation Manual

Hide thumbs Also See for Simon XT:
Table of Contents

Advertisement

Function
Default
Dial delay
30 seconds
Call wait code
Off

Sensors

Table 14 below describes the Sensors menu.
Table 14: Sensors menu
Function
Learn sensors
Delete sensors
Edit sensors
The following instructions tell how to add (learn) sensors, touchpads, and other
system devices into panel memory. The panel recognizes a sensor when you
press a sensor program button, press and release a tamper switch, press a
sensor test button, or put a sensor into alarm. Table 15 on page 42 below
describes the programming method for each device.
When learning (programming) sensors, the panel uses an ascending sequence
starting with 1. You can override this by entering the desired sensor number
using the number keys.
To learn (program) a sensor:
1. Scroll until the display shows System Programming, and then press OK.
The system prompts for an access code.
40
Description
Determines whether the panel delays dialing programmed
phone numbers before sending report (on).
If opening (disarming) reports is on, the panel does not delay
dialing if the system is disarmed before the delay time expires.
The panel dials immediately for both the alarm and opening
report.
Regardless of this option setting, the panel always dials
immediately for fire alarms, AC power failure, and low battery
reports.
The call waiting code is dialed by the panel before a phone
number to disable call waiting. Verify that the end-user has call
waiting with his phone service provider before changing this
option from its default.
CAUTION: Changing this option from its default without call
waiting will prohibit the panel from calling the central station.
The call waiting code is programmed the same way as a dialer
number.
Description
Adds (learns) sensors to panel memory.
Deletes sensors from panel memory.
Edits sensor information in panel memory.
Simon XT Installation Manual