If you press Status and the panel has not heard from all sensors, the displays
shows SN Test Fail or Aborted.
Table 28: Sensor tripping instructions
Sensor
Door/window
Freeze
Water
Carbon monoxide alarm
Glassbreak
Motion sensor
Rate-of-rise heat detector
Shock
Smoke
Personal help button
Key fob
Remote handheld touchpad
Table 29: Minimum beeps
Type of sensor
Wireless intrusion sensors
Wireless smoke and heat sensors
Wireless environmental/panic buttons
Hardwired loops
Emergency buttons (remote handheld touchpads only)
4. Press STATUS. The panel displays Sensor Test Ok.
5. If you press STATUS and the panel has not heard from all sensors, the panel
will display
Sn test fail or aborted
58
Do this
Open the secured door or window.
Remove the sensor cover. Apply ice in a plastic bag to the
sensor (for 10 to 15 minutes). Do not allow the sensor to get
wet.
Press a wet rag or wet finger over both of the round, gold-
plated terminals on the underside of the sensor.
Unplug the CO alarm. Plug it back in, wait 5 seconds, then
press the TEST/RESET button until the unit beeps eight
times.
Trip the glassbreak sensor with an appropriate glassbreak
test tool.
Avoid the motion sensor field of view for 5 minutes, and then
enter its view.
Rub your hand together until warm, and then place one hand
on the detector for 30 seconds.
Tap the glass twice, away from the sensor. Wait at least 10
seconds before testing again.
Press and hold the test button until the system sounds
transmission beeps.
Press and hold the appropriate help button until the light
blinks and the panel sounds for at least seven beeps.
Press and hold the Lock and Unlock buttons simultaneously
for 3 seconds.
Press and hold the two Emergency buttons simultaneously for
3 seconds.
.
Number of beeps
7-8
7-8
7-8
1
7-8
Simon XT Installation Manual