If the test is unsuccessful, the Status button lights and the display shows Comm
Failure within 10 minutes.
If the test is unsuccessful:
1. Check that the panel is connected to the phone jack.
2. Check the phone number programmed into the panel.
3. Perform the communication test again.
4. If the communication test fails again, check the phone connection wiring.

Offsite phone operation

Test the system from a remote phone by calling the panel and using the
commands in Table 30 below.
Table 30: Phone commands
System function
Disarm
Arm doors/windows
Arm motion sensors
Arm doors/windows with no entry delay
Arm motion sensors with latchkey
Arm doors/windows and motion sensors
Arm doors/windows with no entry delay and
motion sensors with latchkey
Specific light on
Specific light off
All lights on
All lights off
System status
Audio verification
Terminate session

Central station communication

After performing sensor and communication tests, check that the system is
reporting alarms successfully to the central station. Table 31 on page 61 provides
a list of sensor/user report codes.
60
Phone command
1
2
3
2 2
3 3
2 3
2 2 3 3
*, <unit number>
#, <unit number>
* *
# #
0
5 plus X (X= a command from Audio
Verification Set)
9
Simon XT Installation Manual