To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the
system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one sensor of each
type (fire, intrusion, etc.) to verify that the appropriate alarms are working
correctly.
4. When you finish testing the system, call the central station to verify that the
alarms were received.
Table 31: Sensor/user report codes
Arm or disarm from
Panel or remote handheld touchpad
Key fob
Panel auxiliary panic
Panel tamper
Panel police panic
Panel fire panic
Dealer access code
Installer access code
Master code
Access codes 1 to 8
Duress code

Two-way voice operation

For the central station operator to initiate an audio session:
1. After the panel has completed reporting the alarm, pick up the CS phone and
press the * button to start the audio session.
2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Note:
Panel voice announcements are silenced during AVM sessions. If the
operator does not terminate the session correctly, panel announcements may not
occur for up to 90 seconds after the operator hangs up.
Simon XT Installation Manual
Reports as user
0
1 to 40 (sensor number)
41
42
43
44
44
45
46
47 to 54
55
61