Conventions; X85; Instrument Firmware Version - Konica Minolta CM-26dG Instruction Manual

Hide thumbs Also See for CM-26dG:
Table of Contents

Advertisement

„ Conventions
This manual describes how to safely operate CM-26d series products using a specific procedure to perform
measurement.
· Viewing Pages
Symbols used in this manual are explained below.
* Explanatory pages are constructed as follows. (The content of the explanatory illustration will differ from the
actual page.)
* Display screenshots used in the explanations may include different content and values, and may have a different
layout than the actual display.
Procedure
Indicates an
operating
procedure.
Settings
Describes ranges
and provides
explanations
regarding settings
for the screen in
question.
Memo
Provides useful
information,
supplementary
explanations, and
similar details.
Notes
Provides essential
information for
correct operation
of the instrument.
Always read this
information before
operating the
instrument.

… Instrument Firmware Version

The firmware version of the instrument can be viewed on the <Instrument Info> screen. For details, refer to P.131
"Displaying the Instrument Information" in this manual.
9
 Display type
Confi gure the display type for the measurement results.
Memo
All display types are selected when the instrument is shipped from the factory.
Operating Procedure
Start the procedure from the <Measurement cond.> - <Display cond.> screen.
1
Use [▲] or [▼] to move the cursor to "Display type",
and then press the [Confi rmation] key.
The <Display type> screen is displayed.
2
Use [▲] or [▼] to move the cursor to the desired
display type, and then press the [Confi rmation] key.
Selections
 Absolute value: Displays the absolute values of the
colorimetric and the gloss values.
 Di erence: Displays the color di erence and gloss value
di erence against the target. The measurement that
failed the pass/fail judgment based on the tolerance will
be highlighted in red.
 Abs. & Di .: Displays the absolute value and the color
di erence and gloss value di erence against the target.
The measurement that failed the pass/fail judgment
based on the tolerance will be highlighted in red.
 Pass/Fail: Determines whether the color di erence and
gloss value di erence related to the target are within the
tolerance range set in advance. If within the tolerance,
the judgment will be displayed as "Pass". If even one
di erence is not within the tolerance, the judgment will
be displayed as "Fail".
 Custom: Displays the display color value and index set under "Custom" as the two illuminants.
 Abs. Graph: Displays a graph of the absolute values of the colorimetric and the gloss values.
 Di . Graph: Displays a graph showing the color di erence and gloss value di erence against the target.
 Spectral Graph: Displays a graph showing the spectral refl ectance. The [Confi rmation] key can be used to
move the wavelength displaying the spectral refl ectance value.
Memo
A check mark means the item is selected.
3
After all settings have been confi gured, use [▲] or [▼] to move the cursor to "OK", and then press
the [Confi rmation] key.
The selection is confi rmed and the screen returns to the previous screen.
Notes
If [ESC] is pressed without pressing the [Confi rmation] key, the settings will not be changed, and the screen
will return to the <Display cond.> screen.
97
Start screen
Indicates the initial
screen from which
the operation is
commenced.
Screenshot
Indicates the state of
the screen when the
operation described
in the procedure to
the left is carried out.