DEVELOPMENT
3.4 SIDE SEAL REPLACEMENT
[C]
1. Remove the development unit.
2. Remove the entrance seal bracket [A] (2 screws).
NOTE:: Do not loosen any screw with white paint [B] fixing the doctor
plate.
3. Peal off the old side seals [C] and clean the parts with alcohol.
4. Install the new seals as shown.
NOTE: Make sure that the corner of each seal are positioned as shown.
5. Reassemble the machine.
NOTE: When reinstalling the entrance seal bracket [A], press and fix it
as shown.
A171R518.img
5-32
[B]
A171R520.img
31 July 1995
A171R519.img