PROCESS CONTROL
Section
Characteristics Causes of Change
Drum
Charge Potential Repeat Stress
Sensitivity
Residual
Voltage
Charge
Charge Potential Dirtiness
Corona
Exposure
Lamp Intensity
Mirror
Reflectivity
Lens Clearness
Development Amount of
Toner Charge
Measure the drum potential of a part
Temperature
that was not exposed (Dark Potential)
Humidity
with the potential sensor and adjust
the charge corona output.
Repeat Stress
Measure the drum potential of a part
Temperature
that was exposed (Light Potential)
Humidity
and adjust the exposure lamp voltage.
Repeat Stress
Measure the drum potential of a part
Temperature
that was erased by the erase lamp
Humidity
(residual voltage) and adjust the
development bias, light potential, and
dark potential
Measure the drum potential of a part
Temperature
that was not exposed (dark potential)
Humidity
and adjust the charge corona output.
Repeat Stress
Measure the drum potential of a part
that was exposed (light potential) and
Dirtiness
adjust the exposure lamp voltage.
Repeat Stress
Measure the reflected light intensity of
Temperature
the ID sensor pattern and adjust the
Humidity
toner density in the development unit.
2-2
31 July 1995
Compensation Method

Hide quick links: