Ricoh FT8680 Service Manual page 167

Table of Contents

Advertisement

INSTALLATION PROCEDURE (COPIER)
[B]
[A]
[I]
[F]
[H]
[G]
11. Remove the charge corona unit [A] (1 connector and 1 clamp) and erase
unit [B].
12. Lower the transport unit by the lever [C] as shown and remove the drum
stay [D] and cleaning unit [E].
13. Remove the drum potential sensor [F] (2 connectors), ID sensor [G], and
drum protection sleeve [H].
14. Reinstall all the units around the drum except for the development unit
and PTC unit.
NOTE: Press the drum shaft [I] to the left and align the cleaning unit to
the guides [J] to prevent the drum damage when reinstalling the
cleaning unit.
A171I525.img
[E]
A171I529.img
3-8
[D]
[C]
[J]
31 July 1995
A171I516.img