Preparing and planning for the upgrade
NN43021-461
Standard 06.03
Procedure 3
Performing a data dump
1
Log into the system.
2
Load the Equipment Data Dump Program (LD 43). At the prompt, enter:
LD 43
3
When "EDD000" appears on the terminal, enter:
EDD
CAUTION — Service Interruption
Loss of Data
If the data dump does not succeed, do not continue.
Contact your technical support organization. You must
correct a data dump problem before the system can be
upgraded.
4
The messages "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" will appear once the data dump is complete.
****
Procedure 4
Performing an ABKO (save the database to floppies)
1
Insert floppy diskettes into BOTH floppy disk drives in each Core IODU/C
or MMDU.
Note: If the file is too large to fit on a single floppy disk, the ABKO
command will compress the data. If the compressed data is still too large
to fit on a single disk, both floppy disks in the two IODU/C drives will be
used. Be sure to insert floppy disks into BOTH IODU/C drives before the
ABKO backup is begun.
June 2014
Load program
Begin the data dump
Exit program
End of Procedure