Removing The System Monitors From The Core Column - Avaya 1000M Upgrade

Cs 1000m sg cp piv
Table of Contents

Advertisement

Page 66 of 212
Performing the upgrade
NN43021-461
Standard 06.03
DSPS x
****
Table 9
Peripheral Signaling Card numbers
Group/
shelf
0 / 0
0 / 1
3
In Core/Net 1 only, faceplate-disable the 3PE, Per Sig and all network
cards.
CAUTION — Service Interruption
Service Interruption
The system can shut down if the system monitors are
not removed. Remove the monitors and keep the
cooling fans ON.
Procedure 13

Removing the system monitors from the Core column

Note: Perform the following procedure for both AC and DC systems
1
In Core 0, software disable the master system monitor (NT8D22):
LD 37
DIS TTY #
2
Remove J3 and J4 cables on Core 0 system monitor.
Note: Do not turn off the blower units in the front of the pedestals
June 2014
Table 9 lists Peripheral Signaling Card values
for "x"
Exit program
Peripheral
Signaling Card
0
1
End of Procedure
Load program
Disable the master system monitor TTY interface
Loops
disabled/enabled
0
16
15
31